Contact us at: 888-888-1212

Part Number #
AUT1054794

Autonics SFDL Series SFDL-S5B-CM20

List Price:
$140.00
/each
Product Description

Autonics Safety Door Switches, model SFDL-S5B-CM20, from the SFDL Series product line.

Specifications

  • Directing opening force: Min. 80N
  • Directing opening distance: Min. 10mm
  • Locking pullout strength: Min. 1,300N
  • Operating speed: 0.05 to 1m/s
  • Operating frequency: Max. 20/min
  • Life cycle_Mechanical: Min. 1,000,000 operations (20/min)
  • Vibration_Malfunction: 0.35mm single amplitude at frequency of 10 to 55Hzin each X,Y,Z direction for 10 min
  • Shock: 1,000m/s² (approx. 100G) in each X, Y, Z direction for 3 times
  • Shock_Malfunction: 1,000m/s² (approx. 100G) in each X, Y, Z direction for 3 times
  • Environment_Ambient temperature: -10 to 55℃, storage: -25 to 65℃
  • Environment_Ambient humidity: 35 to 85% RH, storage: 35 to 85% RH
  • Protection structure: IP67(IEC standerd, except head)
  • Applicable cable: -
  • Material: Head: zinc, case: polyamide 66, operation key: stainless steel 304
  • Sold separately: Operation key, connector cable
  • Weight: Approx. 395g(approx.325g)
  • Rated load voltage & current: Resistive load : 1A/120VAC~, 0.22A/125VDC@(=)</br>Inductive load : AC-15 1A/120VAC~, DC-13 0.22A/125VDC@(=)
  • Dielectric strength_Between the terminals of same polarity: 1.5kV
  • Dielectric strength_Between the terminals of different polarity: 1.5kV
  • Dielectric strength_Between each terminal and non-live part: 2.5kV
  • Insulation resistance: 100MΩ or more (500VDC megger basis)
  • Contact resistance: Max. 200mΩ
  • Life cycle_Electrical: Min. 100,000 operations (125VAC~/1A)
  • Conditional short circuit current: 100A
  • Rated voltage: 24VDC@(=)
  • Current consumption: Supplying power: 0.26A</br>Normal: max. 0.2A (approx. 3 seconds after supplying power)
  • Insulation class: Class E

Downloadable Materials

Write a Review
Brand:

Autonics Safety Door Switches, model SFDL-S5B-CM20, from the SFDL Series product line.

Specifications

  • Directing opening force: Min. 80N
  • Directing opening distance: Min. 10mm
  • Locking pullout strength: Min. 1,300N
  • Operating speed: 0.05 to 1m/s
  • Operating frequency: Max. 20/min
  • Life cycle_Mechanical: Min. 1,000,000 operations (20/min)
  • Vibration_Malfunction: 0.35mm single amplitude at frequency of 10 to 55Hzin each X,Y,Z direction for 10 min
  • Shock: 1,000m/s² (approx. 100G) in each X, Y, Z direction for 3 times
  • Shock_Malfunction: 1,000m/s² (approx. 100G) in each X, Y, Z direction for 3 times
  • Environment_Ambient temperature: -10 to 55℃, storage: -25 to 65℃
  • Environment_Ambient humidity: 35 to 85% RH, storage: 35 to 85% RH
  • Protection structure: IP67(IEC standerd, except head)
  • Applicable cable: -
  • Material: Head: zinc, case: polyamide 66, operation key: stainless steel 304
  • Sold separately: Operation key, connector cable
  • Weight: Approx. 395g(approx.325g)
  • Rated load voltage & current: Resistive load : 1A/120VAC~, 0.22A/125VDC@(=)</br>Inductive load : AC-15 1A/120VAC~, DC-13 0.22A/125VDC@(=)
  • Dielectric strength_Between the terminals of same polarity: 1.5kV
  • Dielectric strength_Between the terminals of different polarity: 1.5kV
  • Dielectric strength_Between each terminal and non-live part: 2.5kV
  • Insulation resistance: 100MΩ or more (500VDC megger basis)
  • Contact resistance: Max. 200mΩ
  • Life cycle_Electrical: Min. 100,000 operations (125VAC~/1A)
  • Conditional short circuit current: 100A
  • Rated voltage: 24VDC@(=)
  • Current consumption: Supplying power: 0.26A</br>Normal: max. 0.2A (approx. 3 seconds after supplying power)
  • Insulation class: Class E

Downloadable Materials