Timers

Select a series

AT11DN series

AT11DN (100-240VAC/24-240VDC) | AT11DN-1 (12VDC) | AT11DN-2 (24VAC/24VDC)

AT11EN series

AT11EN (100-240VAC/24-240VDC) | AT11EN-1 (12VDC) | AT11EN-2 (24VAC/24VDC)

AT8N series

AT8N (100-240VAC/24-240VDC) | AT8N-1 (12VDC) | AT8N-2 (24VAC/24VDC)

AT8PMN series

AT8PMN (200-240VAC) | AT8PMN-7 (100/110VDC)

AT8PSN series

AT8PSN-2(24VAC/24VDC) | AT8PSN-6 (100-120VAC)

AT8SDN series

AT8SDN (100-240VAC/24-240VDC)

ATE8 series

ATE8-41 | ATE8-41D | ATE8-41E | ATE8-43 | ATE8-43D | ATE8-46 | ATE8-46D | ATE8-4C | ATE8-4CD

ATM series

ATM4-230M | ATM4-530M | ATM4-610M | ATM4-610S

ATM4 series

ATM4-210M | ATM4-210S | ATM4-21S | ATM4-230S | ATM4-25S | ATM4-260M | ATM4-260S | ATM4-510M | ATM4-510S | ATM4-51S | ATM4-530S | ATM4-560M | ATM4-560S | ATM4-61S | ATM4-630S | ATM4-63H | ATM4-65S | ATM4-660M | ATM4-660S

ATS11 series

ATS11-21D | ATS11-21E | ATS11-23D | ATS11-23E

ATS8 series

ATS8-21 | ATS8-23

ATS8P series

ATS8P-2M | ATS8P-6S

ATS8W/ATS11W series

ATS11W-11 | ATS11W-21 | ATS11W-23 | ATS8W-11 | ATS8W-21 | ATS8W-23 | ATS8W-41

FSE series

FS4E-1P2 | FS5E-I4

LE4S series

LE4S | LE4SA

LE7M-2 series

LE7M-2B | LE7M-2D

LE8N series

LE8N-BF | LE8N-BN | LE8N-BV-L

Compare model specifications

Compare all 70 timer models

Choose supply, timing ranges, start mode, timing function and output contacts. Listed ranges are selectable settings; open the exact model for full setup, wiring and input requirements. A dash means the field is not specified in the source.

ATS8W/ATS11W Series — 7 models

Exact model Supply Timing ranges / schedule Start mode Timing functions Control outputs
ATS8W-11 12VDC 0.1 to 1 sec, 1 to 10 sec, 0.1 to 1 min, 1 to 10 min, 0.1 to 1 hour, 1 to 10 hour POWER ON START FLICKER Time-limit DPDT (1c): 2 or Instantaneous SPDT (1c): 1 + Time-limit SPDT (1c): 1 depending on output operation mode
ATS11W-23 24VAC 50/60Hz, 24VDC 0.3 to 3 sec, 3 to 30 sec, 0.3 to 3 min, 3 to 30 min, 0.3 to 3 hour, 3 to 30 hour POWER ON START FLICKER Time-limit DPDT (1c): 2 or Instantaneous SPDT (1c): 1 + Time-limit SPDT (1c): 1 depending on output operation mode
ATS11W-21 24VAC 50/60Hz, 24VDC 0.1 to 1 sec, 1 to 10 sec, 0.1 to 1 min, 1 to 10 min, 0.1 to 1 hour, 1 to 10 hour POWER ON START FLICKER Time-limit DPDT (1c): 2 or Instantaneous SPDT (1c): 1 + Time-limit SPDT (1c): 1 depending on output operation mode
ATS8W-23 24VAC 50/60Hz, 24VDC 0.3 to 3 sec, 3 to 30 sec, 0.3 to 3 min, 3 to 30 min, 0.3 to 3 hour, 3 to 30 hour POWER ON START FLICKER Time-limit DPDT (1c): 2 or Instantaneous SPDT (1c): 1 + Time-limit SPDT (1c): 1 depending on output operation mode
ATS8W-21 24VAC 50/60Hz, 24VDC 0.1 to 1 sec, 1 to 10 sec, 0.1 to 1 min, 1 to 10 min, 0.1 to 1 hour, 1 to 10 hour POWER ON START FLICKER Time-limit DPDT (1c): 2 or Instantaneous SPDT (1c): 1 + Time-limit SPDT (1c): 1 depending on output operation mode
ATS11W-11 12VDC 0.1 to 1 sec, 1 to 10 sec, 0.1 to 1 min, 1 to 10 min, 0.1 to 1 hour, 1 to 10 hour POWER ON START FLICKER Time-limit DPDT (1c): 2 or Instantaneous SPDT (1c): 1 + Time-limit SPDT (1c): 1 depending on output operation mode
ATS8W-41 100-240VAC50/60Hz, 24-240VDC 0.1 to 1 sec, 1 to 10 sec, 0.1 to 1 min, 1 to 10 min, 0.1 to 1 hour, 1 to 10 hour POWER ON START FLICKER Time-limit DPDT (1c): 2 or Instantaneous SPDT (1c): 1 + Time-limit SPDT (1c): 1 depending on output operation mode

ATS8P Series — 2 models

Exact model Supply Timing ranges / schedule Start mode Timing functions Control outputs
ATS8P-2M 24VAC 50/60Hz, 24VDC 0.1 to 1 min, 1 to 10 min POWER OFF START POWER OFF DELAY Time-limit SPDT (1c): 2
ATS8P-6S 100-120VAC50/60Hz 0.1 to 1 sec, 1 to 10 sec POWER OFF START POWER OFF DELAY Time-limit SPDT (1c): 2

AT8SDN Series — 1 model

Exact model Supply Timing ranges / schedule Start mode Timing functions Control outputs
AT8SDN 100-240VAC, 24-240VDC 0.5 to 5 sec, 1 to 10 sec, 5 to 50 sec, 10 to 100 sec POWER ON START STAR-DELTA STAR contact: SPST (1a): 1, DELTA contact: SPST (1a): 1

ATE8 Series — 9 models

Exact model Supply Timing ranges / schedule Start mode Timing functions Control outputs
ATE8-41E 100-240VAC50/60Hz, 24-240VDC 0.1 to 1 sec, 1 to 10 sec, 0.1 to 1 min, 1 to 10 min, 0.1 to 1 hour POWER ON START POWER ON DELAY Time-limit SPDT (1c): 1, Instantaneous SPDT (1c): 1
ATE8-4CD 100-240VAC50/60Hz, 24-240VDC 1.2 to 12 sec, 1.2 to 12 min, 2.4 to 24 min, 1.2 to 12 hour, 2.4 to 24 hour POWER ON START POWER ON DELAY Time-limit SPDT (1c): 2
ATE8-46D 100-240VAC50/60Hz, 24-240VDC 0.6 to 6 sec, 6 to 60 sec, 0.6 to 6 min, 6 to 60 min, 0.6 to 6 hour POWER ON START POWER ON DELAY Time-limit SPDT (1c): 2
ATE8-43D 100-240VAC50/60Hz, 24-240VDC 0.3 to 3 sec, 3 to 30 sec, 0.3 to 3 min, 3 to 30 min, 0.3 to 3 hour POWER ON START POWER ON DELAY Time-limit SPDT (1c): 2
ATE8-41D 100-240VAC50/60Hz, 24-240VDC 0.1 to 1 sec, 1 to 10 sec, 0.1 to 1 min, 1 to 10 min, 0.1 to 1 hour POWER ON START POWER ON DELAY Time-limit SPDT (1c): 2
ATE8-4C 100-240VAC50/60Hz, 24-240VDC 1.2 to 12 sec, 1.2 to 12 min, 2.4 to 24 min, 1.2 to 12 hour, 2.4 to 24 hour POWER ON START POWER ON DELAY Time-limit SPDT (1c): 1, Instantaneous SPST (1a): 1
ATE8-46 100-240VAC50/60Hz, 24-240VDC 0.6 to 6 sec, 6 to 60 sec, 0.6 to 6 min, 6 to 60 min, 0.6 to 6 hour POWER ON START POWER ON DELAY Time-limit SPDT (1c): 1, Instantaneous SPST (1a): 1
ATE8-43 100-240VAC50/60Hz, 24-240VDC 0.3 to 3 sec, 3 to 30 sec, 0.3 to 3 min, 3 to 30 min, 0.3 to 3 hour POWER ON START POWER ON DELAY Time-limit SPDT (1c): 1, Instantaneous SPST (1a): 1
ATE8-41 100-240VAC50/60Hz, 24-240VDC 0.1 to 1 sec, 1 to 10 sec, 0.1 to 1 min, 1 to 10 min, 0.1 to 1 hour POWER ON START POWER ON DELAY Time-limit SPDT (1c): 1, Instantaneous SPST (1a): 1

ATM Series — 23 models

Exact model Supply Timing ranges / schedule Start mode Timing functions Control outputs
ATM4-61S 110VAC 0.1 to 1 sec POWER ON START POWER ON DELAY SPDT (1c): 4
ATM4-560M 220VAC 6 to 60 min POWER ON START POWER ON DELAY SPDT (1c): 4
ATM4-530M 220VAC 3 to 30 min POWER ON START POWER ON DELAY SPDT (1c): 4
ATM4-510M 220VAC 1 to 10 min POWER ON START POWER ON DELAY SPDT (1c): 4
ATM4-560S 220VAC 6 to 60 sec POWER ON START POWER ON DELAY SPDT (1c): 4
ATM4-530S 220VAC 3 to 30 sec POWER ON START POWER ON DELAY SPDT (1c): 4
ATM4-510S 220VAC 1 to 10 sec POWER ON START POWER ON DELAY SPDT (1c): 4
ATM4-63H 110VAC 0.3 to 3 hour POWER ON START POWER ON DELAY SPDT (1c): 4
ATM4-51S 220VAC 0.1 to 1 sec POWER ON START POWER ON DELAY SPDT (1c): 4
ATM4-260M 24VDC 6 to 60 min POWER ON START POWER ON DELAY SPDT (1c): 4
ATM4-660M 110VAC 6 to 60 min POWER ON START POWER ON DELAY SPDT (1c): 4
ATM4-230M 24VDC 3 to 30 min POWER ON START POWER ON DELAY SPDT (1c): 4
ATM4-610M 110VAC 1 to 10 min POWER ON START POWER ON DELAY SPDT (1c): 4
ATM4-210M 24VDC 1 to 10 min POWER ON START POWER ON DELAY SPDT (1c): 4
ATM4-660S 110VAC 6 to 60 sec POWER ON START POWER ON DELAY SPDT (1c): 4
ATM4-260S 24VDC 6 to 60 sec POWER ON START POWER ON DELAY SPDT (1c): 4
ATM4-630S 110VAC 3 to 30 sec POWER ON START POWER ON DELAY SPDT (1c): 4
ATM4-230S 24VDC 3 to 30 sec POWER ON START POWER ON DELAY SPDT (1c): 4
ATM4-610S 110VAC 1 to 10 sec POWER ON START POWER ON DELAY SPDT (1c): 4
ATM4-210S 24VDC 1 to 10 sec POWER ON START POWER ON DELAY SPDT (1c): 4
ATM4-65S 110VAC 0.5 to 5 sec POWER ON START POWER ON DELAY SPDT (1c): 4
ATM4-25S 24VDC 0.5 to 5 sec POWER ON START POWER ON DELAY SPDT (1c): 4
ATM4-21S 24VDC 0.1 to 1 sec POWER ON START POWER ON DELAY SPDT (1c): 4

ATN Series — 9 models

Exact model Supply Timing ranges / schedule Start mode Timing functions Control outputs
AT11EN 100-240VAC, 24-240VDC 0.05 to 0.5 sec, 0.1 to 1 sec, 0.5 to 5 sec, 1 to 10 sec, 0.05 to 0.5 min, 0.1 to 1 min, 0.5 to 5 min, 1 to 10 min, 0.05 to 0.5 hour, 0.1 to 1 hour, 0.5 to 5 hour, 1 to 10 hour, 5 to 50 hour, 10 to 100 hour SIGNAL ON START SIGNAL ON DELAY, SIGNAL OFF DELAY, SIGNAL ON-OFF DELAY, FLICKER, INTERVAL Time-limit SPDT (1c): 1, Instantaneous SPDT (1c): 1
AT11EN-2 24VAC, 24VDC 0.05 to 0.5 sec, 0.1 to 1 sec, 0.5 to 5 sec, 1 to 10 sec, 0.05 to 0.5 min, 0.1 to 1 min, 0.5 to 5 min, 1 to 10 min, 0.05 to 0.5 hour, 0.1 to 1 hour, 0.5 to 5 hour, 1 to 10 hour, 5 to 50 hour, 10 to 100 hour SIGNAL ON START SIGNAL ON DELAY, SIGNAL OFF DELAY, SIGNAL ON-OFF DELAY, FLICKER, INTERVAL Time-limit SPDT (1c): 1, Instantaneous SPDT (1c): 1
AT11EN-1 12VDC 0.05 to 0.5 sec, 0.1 to 1 sec, 0.5 to 5 sec, 1 to 10 sec, 0.05 to 0.5 min, 0.1 to 1 min, 0.5 to 5 min, 1 to 10 min, 0.05 to 0.5 hour, 0.1 to 1 hour, 0.5 to 5 hour, 1 to 10 hour, 5 to 50 hour, 10 to 100 hour SIGNAL ON START SIGNAL ON DELAY, SIGNAL OFF DELAY, SIGNAL ON-OFF DELAY, FLICKER, INTERVAL Time-limit SPDT (1c): 1, Instantaneous SPDT (1c): 1
AT11DN 100-240VAC, 24-240VDC 0.05 to 0.5 sec, 0.1 to 1 sec, 0.5 to 5 sec, 1 to 10 sec, 0.05 to 0.5 min, 0.1 to 1 min, 0.5 to 5 min, 1 to 10 min, 0.05 to 0.5 hour, 0.1 to 1 hour, 0.5 to 5 hour, 1 to 10 hour, 5 to 50 hour, 10 to 100 hour SIGNAL ON START SIGNAL ON DELAY, SIGNAL OFF DELAY, SIGNAL ON-OFF DELAY, FLICKER, INTERVAL Time-limit SPDT (1c): 2
AT11DN-2 24VAC, 24VDC 0.05 to 0.5 sec, 0.1 to 1 sec, 0.5 to 5 sec, 1 to 10 sec, 0.05 to 0.5 min, 0.1 to 1 min, 0.5 to 5 min, 1 to 10 min, 0.05 to 0.5 hour, 0.1 to 1 hour, 0.5 to 5 hour, 1 to 10 hour, 5 to 50 hour, 10 to 100 hour SIGNAL ON START SIGNAL ON DELAY, SIGNAL OFF DELAY, SIGNAL ON-OFF DELAY, FLICKER, INTERVAL Time-limit SPDT (1c): 2
AT11DN-1 12VDC 0.05 to 0.5 sec, 0.1 to 1 sec, 0.5 to 5 sec, 1 to 10 sec, 0.05 to 0.5 min, 0.1 to 1 min, 0.5 to 5 min, 1 to 10 min, 0.05 to 0.5 hour, 0.1 to 1 hour, 0.5 to 5 hour, 1 to 10 hour, 5 to 50 hour, 10 to 100 hour SIGNAL ON START SIGNAL ON DELAY, SIGNAL OFF DELAY, SIGNAL ON-OFF DELAY, FLICKER, INTERVAL Time-limit SPDT (1c): 2
AT8N 100-240VAC, 24-240VDC 0.05 to 0.5 sec, 0.1 to 1 sec, 0.5 to 5 sec, 1 to 10 sec, 0.05 to 0.5 min, 0.1 to 1 min, 0.5 to 5 min, 1 to 10 min, 0.05 to 0.5 hour, 0.1 to 1 hour, 0.5 to 5 hour, 1 to 10 hour, 5 to 50 hour, 10 to 100 hour POWER ON START POWER ON DELAY, FLICKER, INTERVAL Time-limit DPDT (1c): 2 or Instantaneous SPDT (1c): 1 + Time-limit SPDT (1c): 1 depending on output operation mode
AT8N-2 24VAC, 24VDC 0.05 to 0.5 sec, 0.1 to 1 sec, 0.5 to 5 sec, 1 to 10 sec, 0.05 to 0.5 min, 0.1 to 1 min, 0.5 to 5 min, 1 to 10 min, 0.05 to 0.5 hour, 0.1 to 1 hour, 0.5 to 5 hour, 1 to 10 hour, 5 to 50 hour, 10 to 100 hour POWER ON START POWER ON DELAY, FLICKER, INTERVAL Time-limit DPDT (1c): 2 or Instantaneous SPDT (1c): 1 + Time-limit SPDT (1c): 1 depending on output operation mode
AT8N-1 12VDC 0.05 to 0.5 sec, 0.1 to 1 sec, 0.5 to 5 sec, 1 to 10 sec, 0.05 to 0.5 min, 0.1 to 1 min, 0.5 to 5 min, 1 to 10 min, 0.05 to 0.5 hour, 0.1 to 1 hour, 0.5 to 5 hour, 1 to 10 hour, 5 to 50 hour, 10 to 100 hour POWER ON START POWER ON DELAY, FLICKER, INTERVAL Time-limit DPDT (1c): 2 or Instantaneous SPDT (1c): 1 + Time-limit SPDT (1c): 1 depending on output operation mode

LE7M-2 Series — 2 models

Exact model Supply Timing ranges / schedule Start mode Timing functions Control outputs
LE7M-2D 100-240VAC 50/60Hz Weekly 64 steps, Yearly 32 steps — ON/OFF, CYCLE, PULSE SPDT (1c): 2
LE7M-2B 100-240VAC 50/60Hz Weekly 64 steps, Yearly 32 steps — ON/OFF, CYCLE, PULSE SPDT (1c): 2

ATS Series — 6 models

Exact model Supply Timing ranges / schedule Start mode Timing functions Control outputs
ATS11-23E 24VAC 50/60Hz, 24VDC 0.3 to 3 sec, 3 to 30 sec, 0.3 to 3 min, 3 to 30 min, 0.3 to 3 hour, 3 to 30 hour SIGNAL ON START SIGNAL ON DELAY, SIGNAL OFF DELAY, SIGNAL ON-OFF DELAY, FLICKER, INTERVAL Time-limit SPDT (1c): 1, Instantaneous SPDT (1c): 1
ATS11-21E 24VAC 50/60Hz, 24VDC 0.1 to 1 sec, 1 to 10 sec, 0.1 to 1 min, 1 to 10 min, 0.1 to 1 hour, 1 to 10 hour SIGNAL ON START SIGNAL ON DELAY, SIGNAL OFF DELAY, SIGNAL ON-OFF DELAY, FLICKER, INTERVAL Time-limit SPDT (1c): 1, Instantaneous SPDT (1c): 1
ATS11-23D 24VAC 50/60Hz, 24VDC 0.3 to 3 sec, 3 to 30 sec, 0.3 to 3 min, 3 to 30 min, 0.3 to 3 hour, 3 to 30 hour SIGNAL ON START SIGNAL ON DELAY, SIGNAL OFF DELAY, SIGNAL ON-OFF DELAY, FLICKER, INTERVAL Time-limit SPDT (1c): 2
ATS11-21D 24VAC 50/60Hz, 24VDC 0.1 to 1 sec, 1 to 10 sec, 0.1 to 1 min, 1 to 10 min, 0.1 to 1 hour, 1 to 10 hour SIGNAL ON START SIGNAL ON DELAY, SIGNAL OFF DELAY, SIGNAL ON-OFF DELAY, FLICKER, INTERVAL Time-limit SPDT (1c): 2
ATS8-23 24VAC 50/60Hz, 24VDC 0.3 to 3 sec, 3 to 30 sec, 0.3 to 3 min, 3 to 30 min, 0.3 to 3 hour, 3 to 30 hour POWER ON START POWER ON DELAY, FLICKER, INTERVAL Time-limit DPDT (1c): 2 or Instantaneous SPDT (1c): 1 + Time-limit SPDT (1c): 1 depending on output operation mode
ATS8-21 24VAC 50/60Hz, 24VDC 0.1 to 1 sec, 1 to 10 sec, 0.1 to 1 min, 1 to 10 min, 0.1 to 1 hour, 1 to 10 hour POWER ON START POWER ON DELAY, FLICKER, INTERVAL Time-limit DPDT (1c): 2 or Instantaneous SPDT (1c): 1 + Time-limit SPDT (1c): 1 depending on output operation mode

LE4S Series — 2 models

Exact model Supply Timing ranges / schedule Start mode Timing functions Control outputs
LE4SA 24-240VAC, 24-240VDC 0.01 sec to 9.999 sec, 0.01 sec to 99.99 sec, 0.1 sec to 999.9 sec, 1 sec to 9999 sec, 0 min 1 sec to 99 min 59 sec, 0.1 min to 999.9 min, 1 min to 9999 min, 0 hour 1 min to 99 hour 59 min, 0.01 hour to 99.99 hour, 0.1 hour to 999.9 hour POWER ON START ON DELAY, INTERVAL, FLICKER, STAR-DELTA, TWIN Time-limit SPDT (1c): 2 or Time-limit SPDT (1c): 1 + Instantaneous SPDT (1c): 1 depending on output operation mode
LE4S 24-240VAC, 24-240VDC 0.01 sec to 9.999 sec, 0.01 sec to 99.99 sec, 0.1 sec to 999.9 sec, 1 sec to 9999 sec, 0 min 1 sec to 99 min 59 sec, 0.1 min to 999.9 min, 1 min to 9999 min, 0 hour 1 min to 99 hour 59 min, 0.01 hour to 99.99 hour, 0.1 hour to 999.9 hour SIGNAL ON START ON DELAY, INTERVAL, FLICKER, ON-OFF DELAY, OFF DELAY Time-limit SPDT (1c): 1

FSE Series — 2 models

Exact model Supply Timing ranges / schedule Start mode Timing functions Control outputs
FS4E-1P2 24VAC 50/60Hz, 24-48VDC 0.01 sec to 99.99 sec, 0.1 sec to 999.9 sec, 1 sec to 9999 sec, 1 sec to 99 min 59 sec, 0.1 min to 999.9 min, 1 min to 99 hour 59 min, 0.1 hour to 999.9 hour, 1 hour to 9999 hour POWER ON START POWER ON DELAY, FLICKER 1-stage preset; Relay SPDT (1c): 1
FS5E-I4 100-240VAC 50/60Hz 0.01 sec to 99.99 sec, 0.1 sec to 999.9 sec, 1 sec to 9999 sec, 1 sec to 99 min 59 sec, 0.1 min to 999.9 min, 1 min to 99 hour 59 min, 0.1 hour to 999.9 hour, 1 hour to 9999 hour — POWER ON DELAY, FLICKER Indicator

LE8N Series — 3 models

Exact model Supply Timing ranges / schedule Start mode Timing functions Control outputs
LE8N-BF Built-in battery(over 10 years) 1 sec to 9999 hour 59 min 59 sec, 0.1 min to 99999 hour 59.9 min, 1 min to 999999 hour 59 min, 1 min to 9999 day 23 hour 59 min, 0.1 hour to 9999 day 23.9 hour, 1 sec to 99999999 sec, 0.1 min to 9999 hour 59.9 min, 1 min to 99999 hour 59 min POWER ON START — Indicator
LE8N-BV-L Built-in battery(over 10 years) 1 sec to 9999 hour 59 min 59 sec, 0.1 min to 99999 hour 59.9 min, 1 min to 999999 hour 59 min, 1 min to 9999 day 23 hour 59 min, 0.1 hour to 9999 day 23.9 hour, 1 sec to 99999999 sec, 0.1 min to 9999 hour 59.9 min, 1 min to 99999 hour 59 min POWER ON START — Indicator
LE8N-BN Built-in battery(over 10 years) 1 sec to 9999 hour 59 min 59 sec, 0.1 min to 99999 hour 59.9 min, 1 min to 999999 hour 59 min, 1 min to 9999 day 23 hour 59 min, 0.1 hour to 9999 day 23.9 hour, 1 sec to 99999999 sec, 0.1 min to 9999 hour 59.9 min, 1 min to 99999 hour 59 min POWER ON START — Indicator

AT8PSN/AT8PMN Series — 4 models

Exact model Supply Timing ranges / schedule Start mode Timing functions Control outputs
AT8PMN-7 100/110VDC 00.5sec, 01sec, 05sec, 010sec, 00.5min, 01min, 05min, 010min POWER OFF START POWER OFF DELAY Time-limit SPDT (1c): 2
AT8PMN 200-240VAC50/60Hz 0.05 to 0.5 sec, 0.1 to 1 sec, 0.5 to 5 sec, 1 to 10 sec POWER OFF START POWER OFF DELAY Time-limit SPDT (1c): 2
AT8PSN-6 100-120VAC50/60Hz 00.5sec, 01sec, 05sec, 010sec, 00.5min, 01min, 05min, 010min POWER OFF START POWER OFF DELAY Time-limit SPDT (1c): 2
AT8PSN-2 24VAC 50/60Hz, 24VDC 00.5sec, 01sec, 05sec, 010sec, 00.5min, 01min, 05min, 010min POWER OFF START POWER OFF DELAY Time-limit SPDT (1c): 2