Contact us at: (800) 732-8704

Shop ProductsView all categories →
Displacement Sensor

Select a series

BD series

BD-030 | BD-030R | BD-065 | BD-065R | BD-100 | BD-100R | BD-300 | BD-600 | BD-A1

BD-C series

BD-CRS

Compare model specifications

Compare Displacement Models

Compare all 10 current visible native listings: eight optical heads, one display/output unit and one communication module. Compare heads using the optical method and their own reference distance, maximum measurement range, resolution and stated linearity interval. The electronic units have separate role-specific tables and are not presented as standalone measuring heads.

Optical sensor heads — 8 models

Exact model Listed optical method Listed reference distance Listed maximum measurement range Listed resolution Listed linearity / stated interval Listed supply source Listed laser class Listed protection / exceptions
BD-030 Diffuse reflection 30mm 20 to 40mm 1㎛ 0.1% F.S. (in 25 to 35mm) Using power from the amplifier unit. Class 1 (IEC/EN), Class I (FDA(CDRH) CFR Part 1002) IP67 (IEC Standards, except connector of extension cable)
BD-030R Regular reflection 27.3 mm 24.9 to 29.7 mm 1㎛ ± 0.1% of F.S. Using power from the amplifier unit. Class 1 (IEC/EN), Class I (FDA(CDRH) CFR Part 1002) IP67 (IEC Standards, except connector of extension cable)
BD-065 Diffuse reflection 65mm 50 to 80mm 2㎛ 0.1% F.S. (in 55 to 75mm) Using power from the amplifier unit. Class 2 (IEC/EN), Class II (FDA(CDRH) CFR Part 1002) IP67 (IEC Standards, except connector of extension cable)
BD-065R Regular reflection 62.9 mm 56.9 to 68.9 mm 2㎛ ± 0.1% of F.S. Using power from the amplifier unit. Class 1 (IEC/EN), Class I (FDA(CDRH) CFR Part 1002) IP67 (IEC Standards, except connector of extension cable)
BD-100 Diffuse reflection 100mm 70 to 130mm 4㎛ 0.15% F.S. (in 80 to 120mm) Using power from the amplifier unit. Class 2 (IEC/EN), Class II (FDA(CDRH) CFR Part 1002) IP67 (IEC Standards, except connector of extension cable)
BD-100R Regular reflection 98.3 mm 86.3 to 110.3 mm 4㎛ ± 0.15% of F.S. Using power from the amplifier unit. Class 1 (IEC/EN), Class I (FDA(CDRH) CFR Part 1002) IP67 (IEC Standards, except connector of extension cable)
BD-300 Diffuse reflection 300mm 160 ~ 450 mm 20 ㎛ ± 0.25% of F.S. Using power from the amplifier unit. Class 2 (IEC/EN), Class II (FDA (CDRH) CFR Part 1002) IP67 (IEC Standards, except connector of extension cable)
BD-600 Diffuse reflection 600mm 250 ~ 1,000 mm 40 ㎛ ± 0.25% of F.S. (250 ~ 600 mm) ; ± 0.5% of F.S. (600 ~ 1,000 mm) Using power from the amplifier unit. Class 2 (IEC/EN), Class II (FDA (CDRH) CFR Part 1002) IP67 (IEC Standards, except connector of extension cable)

Display / output unit — 1 model

Exact model Listed supply / converter condition Listed judgment output Listed alarm output Listed voltage output Listed current output / source status Listed response settings Listed display Listed connection
BD-A1 10-30VDC@(=) ±10% (When connecting BD-C Series communication converter, 12-30VDC@(=)) NPN or PNP open collector output (Load current: Max. 100mA) NPN or PNP open collector output (Load current: Max. 100mA) -5 - 5 V, 0 - 5 V, 1 - 5 V (resistance: 100 Ω, ± 0.05% F.S., at 10 V) Source review required: malformed native current-output field 0.33, 0.5, 1, 2, 5 ms (5-step adjustment) Dual display by 6-digit, 11-segment LED Connector type

Communication module — 1 model

Exact model Listed communication Listed communication speed Listed supply source Listed consumption Listed indicators
BD-CRS RS-232C, RS-485 9600, 19200, 38400, 115200bps (default) Using power from the amplifier unit. Max. 2.3W 4 LED status indicators

Values and qualifiers are reproduced from native model descriptions, not inferred from suffixes. A maximum measurement range is not a guarantee of the same linearity across that entire interval: retain each stated interval and condition. Resolution, linearity and display increment are distinct and must not be substituted for one another. Power supplied by the amplifier is not treated as a direct DC input to a head. The display/output unit lists a different supply condition when a BD-C converter is connected; that condition is retained. One malformed current-output field is flagged for source review rather than silently corrected. Not specified in listing means absent or incomplete source data. Laser classes and protection exceptions are listed source data, not an independent safety certification; follow the exact manufacturer documentation for installation and use. Confirm system compatibility and ordering options on each exact model page and applicable manufacturer documentation. Existing product records, listings and content remain unchanged.

10 Results found
​